Refrigerated Air Dryer
SEAH INDUSRTRY
Air cooled type
Warm and moisture air enters the air-to-air heat exchanger, where it is precooled without going cool air.
The cooling of air causes moisture condensation and minimizes heat load on the refrigeration system.
This condensate is removed(larger sizes), and air flows to the air-refrigerant heat exchanger.
Pre cooling allows use of a smaller refrigeration unit and lowers the cost of drying. the precooled air is further
cooled to the 35°F range in the air-to-refrigerant heat exchanger. The cooling capacity is provided by the
refrigeration system.
The cooling of compressed air causes condensation of moisture which is separated by a highly efficient
centrifugal separator. Condensed moisture is drained automatically by an automatic drain from the separator.
The cold air flows through the air-to-air heat exchanger, where it is re-heated by the incoming warm air.
Reheating increases the volume of air, prevents the sweating of air lines, and lowers the relative humidity
of the air, thus enabling it to do more work.
- It is made of graphic control panel, on/off switch, on/off lamp, refrigerant gauge and , air gauge and
the operation situation can be checkable at any times.
- As for the products more than middle size, there is the function to monitor the temperature on each parts of
refirgerating cycle and therefore, the temperature can be detected automatically or manually. Futhermore, as the
distinction for defects of the products and utilizing time is indicated, it's very convenient to repair and maintenance it.
- Since power drain to discharge the dedensate forcibly is equipped with 1st and 2nd condensate,
the condensate is discharged completely and surely.
- Because the specific heat exchanger, cross-wave baffle fin, which performance was already proven,
is equipped with, the heat exchange for miniaturazion and weight lightening came true.
- All exterinal surface was powder-painted and there are no corrosion and scratch by exterinal stroke
and it is also elegant.
- Design, inspection, production and test are made based on the strict standard and a best quality and
performance are guaranteed accordging to through post management.
- Operation condition |
|
* Inlet temperature : 38°C * Ambient temperature : 38°C * Dew point at pressure : 4°C / 10°C * Inlet pressure : 7 kgf/cm2 * Differantial pressure : 0.3kgf/cm2 |
Model |
SDA 05 |
SDA 07 |
SDA 10 |
SDA 15 |
SDA 20 |
SDA 25 |
SDA 30 |
SDA 35 |
SDA 50 |
SDA 75 | |
C.pipe dia.(in/out) |
(A) |
15 |
15 |
25 |
25 |
25 |
25 |
25 |
25 |
40 |
50 |
Application comp. |
Hp |
1~5 |
5~7 |
7~10 |
10~15 |
15~20 |
20~25 |
25~30 |
30~35 |
35~50 |
50~75 |
Capacity |
Nm3/min |
0.51 |
0.79 |
1.0 |
1.53 |
2.6 |
3.2 |
3.9 |
4.7 |
6.7 |
10.5 |
Refrigeration comp. |
Hp |
1/5 |
1/4 |
1/3 |
1/3 |
3/8 |
1/2 |
3/4 |
3/4 |
1 |
1-1/2 |
Current |
Ampere |
2.8 |
2.8 |
3.6 |
5.0 |
5.0 |
5.4 |
6.2 |
6.2 |
10.2 |
13.2 |
Power cosumption |
kw |
0.46 |
0.46 |
0.62 |
0.62 |
0.72 |
0.88 |
1.30 |
1.30 |
1.60 |
2.10 |
Dimension ( mm ) |
Width |
630 |
630 |
630 |
730 |
730 |
700 |
700 |
700 |
800 |
800 |
Length |
270 |
270 |
270 |
350 |
350 |
350 |
350 |
350 |
400 |
400 | |
Height |
520 |
520 |
520 |
54 |
540 |
680 |
680 |
680 |
800 |
800 | |
Weight |
kg |
36 |
36 |
38 |
56 |
56 |
70 |
72 |
72 |
103 |
137 |
Model |
SDA 130 |
SDA 150 |
SDA 170 |
SDA 200 |
SDA 250 |
SDA 300 |
SDA 400 |
SDA 500 |
SDA 600 | |
C.pipe dia.(in/out) |
(A) |
65 |
65 |
65 |
80 |
80 |
100 |
100 |
150 |
150 |
Application comp. |
Hp |
100~130 |
130~150 |
150~170 |
170~200 |
200~250 |
250~300 |
300~400 |
400~500 |
500~600 |
Capacity |
Nm3/min |
18 |
21 |
24 |
30 |
39 |
47 |
56 |
66 |
85 |
Refrigeration comp. |
Hp |
3 |
3 |
4 |
4 |
5 |
5 |
10 |
16 |
16 |
Current |
Ampere |
12.4 |
12.4 |
16.0 |
16.0 |
20.7 |
20.7 |
31.2 |
46.2 |
46.2 |
Power consumption |
kw |
3.0 |
3.0 |
4.6 |
5.1 |
8.5 |
8.5 |
10.0 |
16.0 |
18.0 |
Dimension ( mm ) |
Width |
620 |
620 |
700 |
700 |
770 |
770 |
1,150 |
1,150 |
1,150 |
Length |
1,150 |
1,150 |
1,200 |
1,200 |
1,350 |
1,350 |
1,900 |
1,900 |
1,900 | |
Height |
1,200 |
1,200 |
1,270 |
1,270 |
1,360 |
1,360 |
1,700 |
1,700 |
1,700 | |
Weight |
kg |
180 |
200 |
350 |
490 |
500 |
860 |
910 |
940 |
1,100 |
Model |
SDA 800 |
SDA 1000 |
SDA 1200 |
SDA 1500 |
SDA 2000 | SDA 2500 | |
C.pipe dia.(in/out) | (A) | 200 | 200 | 200 | 200 | 200 | 200 |
Application comp. | Hp | 800 | 1,000 | 1,200 | 1,500 | 2,000 | 2,500 |
Capacity | Nm3/min | 100 | 134 | 156 | 195 | 267 | 333 |
Refrigeration comp. | Hp | 15 | 20 | 20 | 25 | 30 | 30 |
Current | Ampere | 31 | 38 | 42 | 46 | 57 | 60 |
Power consumption | kw | 15.3 | 20.5 | 20.8 | 29.3 | 36.0 | 38.2 |
Dimension ( mm ) | Width | 1,000 | 1,000 | 1,000 | 1,000 | 1,000 | 2,000 |
Length | 2,260 | 2,260 | 2,260 | 2,800 | 2,800 | 3,260 | |
Height | 1,895 | 1,895 | 1,895 | 1,915 | 1,915 | 1,940 | |
Weight | kg | 980 | 1,100 | 1,180 | 1,700 | 1,900 | 2,300 |
※ "C.pipe dia." is the diameter of connection pipe.
※ "Application. comp." is the application cmpressor.
※ "Refrigeration comp." is the refrigeration compressor.
※ Dew point at pressure : 4°C ~ 10°C
※ Fluid name : Compressed air
※ In let temperature : 2~40°C
※ Ambient temperature : 2~40°C
※ Max. pressure : 9.9kgf/cm2
※ Refrigerant : R134a ( SDA 05 ~ SDA 20 ), R-22 ( SDA 25 ~ SDA 1000 )
※ Condenser : Fin tube type
※ Refrigerant control device : Expension valve
※ Temperature control Device : Hot gas by-pass valve
※ Heat exchanger type : Cross wave baffle fin type( SDA 25 ~ SDA 300 ),
Shell & fin coil type ( SDA 05 ~ SDA 20 , SDA 400 ~ SDA 600 ).
※ Voltage : 220V / 380V / 440V, 1Ph, 60Hz ( SDA 05 ~ SDA 75),
220V / 380V / 440V, 3Ph, 60Hz ( SDA 100 ~ SDA 600.
1) R-404A as alternative refrigerant of R-22 is ordering production
2) Disposal flux is the capacity under 60hz
Electonical specification under 50hz is ordering production.
The capacity under 50Hz is about 83%.
3) Utilizing pressure over 9.9kgf/cm2 is also ordering production.
4) The large capacity more than above type can be manufactured accordering to ordering.
5) Heat exchanger equipped with dryer more than "SDA 50" is test acquired by
KOSHA ( Korea Occupational Safety and Health Agency )
6) Be careful that above specification can be changeable at any time without any prior notice